------------------------------------------------------------------------------- - OrbitalSystems::tracker_child 1.159 starting at Mon Jun 16 03:27:54 2025. STATUS: Starting to track pass for 'NOAA 19'. Pedestal: Pedestal_1(24_AEBP). Start Az, El: 206.60599730778, 4.2877948413937. STATUS: LOS date is known for this pass. Tracking until 16-Jun-2025 03:39:06 STATUS: Running in mode: EOSFES. STATUS: Using TLE: NOAA 19;1 33591U 09005A 25166.57507177 .00000153 00000+0 10577-3 0 9995;2 33591 98.9970 231.3131 0013423 351.5103 8.5839 14.13377128842699 STATUS: OrbitalSystems::Hardware::Pedestal::DownlinkController::Setup_Downlink(): Setting up AOS downlink parameters for Pedestal_1(24_AEBP) and NOAA 19 STATUS: OrbitalSystems::Hardware::Pedestal::DownlinkController::Setup_Downlink(): Successfully set AOS downlink parameter LRD_RX_1->mode( HRPT ). STATUS: OrbitalSystems::Hardware::Pedestal::DownlinkController::Setup_Downlink(): Successfully set AOS downlink parameter LRD_RX_1->offset( 1562.500 ). STATUS: OrbitalSystems::Hardware::Pedestal::DownlinkController::Setup_Downlink(): Successfully set AOS downlink parameter LRD_RX_1->frequency( 1698.000 ). STATUS: OrbitalSystems::Hardware::Pedestal::DownlinkController::Setup_Downlink(): Successfully set AOS downlink parameter LRD_Ingestor_1->ingest( tcp://localhost:12001,autofile://NOAA19 ). STATUS: 16-Jun-2025 03:28:04: ACU Position: 207.45, 4.98 STATUS: LRD_RX_1->signal_level() = -47.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:04: ACU Position: 207.49, 4.98 STATUS: LRD_RX_1->signal_level() = -47.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:05: ACU Position: 207.57, 4.98 STATUS: LRD_RX_1->signal_level() = -47.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:06: ACU Position: 207.62, 4.98 STATUS: LRD_RX_1->signal_level() = -47.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:06: ACU Position: 207.67, 4.99 STATUS: LRD_RX_1->signal_level() = -47.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:07: ACU Position: 207.72, 5.04 STATUS: LRD_RX_1->signal_level() = -46.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:08: ACU Position: 207.8, 5.06 STATUS: LRD_RX_1->signal_level() = -46.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:08: ACU Position: 207.84, 5.1 STATUS: LRD_RX_1->signal_level() = -47.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:09: ACU Position: 207.9, 5.15 STATUS: LRD_RX_1->signal_level() = -48.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:10: ACU Position: 207.95, 5.19 STATUS: LRD_RX_1->signal_level() = -47.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:10: ACU Position: 208.02, 5.22 STATUS: LRD_RX_1->signal_level() = -47.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:11: ACU Position: 208.09, 5.26 STATUS: LRD_RX_1->signal_level() = -47.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:11: ACU Position: 208.14, 5.28 STATUS: LRD_RX_1->signal_level() = -47.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:12: ACU Position: 208.2, 5.32 STATUS: LRD_RX_1->signal_level() = -47.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:13: ACU Position: 208.25, 5.38 STATUS: LRD_RX_1->signal_level() = -47.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:13: ACU Position: 208.33, 5.4 STATUS: LRD_RX_1->signal_level() = -47.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:14: ACU Position: 208.38, 5.44 STATUS: LRD_RX_1->signal_level() = -47.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:15: ACU Position: 208.43, 5.49 STATUS: LRD_RX_1->signal_level() = -47.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:15: ACU Position: 208.49, 5.53 STATUS: LRD_RX_1->signal_level() = -47.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:16: ACU Position: 208.54, 5.58 STATUS: LRD_RX_1->signal_level() = -48.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:17: ACU Position: 208.61, 5.6 STATUS: LRD_RX_1->signal_level() = -48.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:17: ACU Position: 208.67, 5.63 STATUS: LRD_RX_1->signal_level() = -48.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:18: ACU Position: 208.72, 5.66 STATUS: LRD_RX_1->signal_level() = -48.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:19: ACU Position: 208.78, 5.72 STATUS: LRD_RX_1->signal_level() = -48.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:19: ACU Position: 208.83, 5.75 STATUS: LRD_RX_1->signal_level() = -48.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:20: ACU Position: 208.91, 5.79 STATUS: LRD_RX_1->signal_level() = -49.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:21: ACU Position: 208.95, 5.83 STATUS: LRD_RX_1->signal_level() = -49.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:21: ACU Position: 209.01, 5.87 STATUS: LRD_RX_1->signal_level() = -49.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:22: ACU Position: 209.09, 5.92 STATUS: LRD_RX_1->signal_level() = -49.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:23: ACU Position: 209.14, 5.94 STATUS: LRD_RX_1->signal_level() = -49.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:23: ACU Position: 209.2, 5.98 STATUS: LRD_RX_1->signal_level() = -49.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:24: ACU Position: 209.27, 6.04 STATUS: LRD_RX_1->signal_level() = -50.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:25: ACU Position: 209.33, 6.07 STATUS: LRD_RX_1->signal_level() = -50.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:25: ACU Position: 209.39, 6.11 STATUS: LRD_RX_1->signal_level() = -49.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:26: ACU Position: 209.45, 6.15 STATUS: LRD_RX_1->signal_level() = -49.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:26: ACU Position: 209.54, 6.18 STATUS: LRD_RX_1->signal_level() = -49.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:27: ACU Position: 209.6, 6.22 STATUS: LRD_RX_1->signal_level() = -50.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:28: ACU Position: 209.66, 6.26 STATUS: LRD_RX_1->signal_level() = -50.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:28: ACU Position: 209.74, 6.3 STATUS: LRD_RX_1->signal_level() = -50.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:29: ACU Position: 209.8, 6.33 STATUS: LRD_RX_1->signal_level() = -50.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:30: ACU Position: 209.85, 6.37 STATUS: LRD_RX_1->signal_level() = -50.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:30: ACU Position: 209.92, 6.41 STATUS: LRD_RX_1->signal_level() = -50.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:31: ACU Position: 209.98, 6.47 STATUS: LRD_RX_1->signal_level() = -51.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:32: ACU Position: 210.06, 6.5 STATUS: LRD_RX_1->signal_level() = -51.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:32: ACU Position: 210.12, 6.53 STATUS: LRD_RX_1->signal_level() = -51.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:33: ACU Position: 210.18, 6.58 STATUS: LRD_RX_1->signal_level() = -51.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:34: ACU Position: 210.26, 6.61 STATUS: LRD_RX_1->signal_level() = -51.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:34: ACU Position: 210.32, 6.65 STATUS: LRD_RX_1->signal_level() = -51.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:35: ACU Position: 210.37, 6.7 STATUS: LRD_RX_1->signal_level() = -51.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:36: ACU Position: 210.44, 6.73 STATUS: LRD_RX_1->signal_level() = -52.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:36: ACU Position: 210.51, 6.76 STATUS: LRD_RX_1->signal_level() = -52.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:37: ACU Position: 210.58, 6.83 STATUS: LRD_RX_1->signal_level() = -52.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:38: ACU Position: 210.66, 6.85 STATUS: LRD_RX_1->signal_level() = -52.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:38: ACU Position: 210.71, 6.89 STATUS: LRD_RX_1->signal_level() = -52.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:39: ACU Position: 210.78, 6.94 STATUS: LRD_RX_1->signal_level() = -52.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:40: ACU Position: 210.84, 6.97 STATUS: LRD_RX_1->signal_level() = -53.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:40: ACU Position: 210.9, 7.02 STATUS: LRD_RX_1->signal_level() = -52.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:41: ACU Position: 210.99, 7.05 STATUS: LRD_RX_1->signal_level() = -53.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:42: ACU Position: 211.04, 7.08 STATUS: LRD_RX_1->signal_level() = -52.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:42: ACU Position: 211.1, 7.13 STATUS: LRD_RX_1->signal_level() = -53.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:43: ACU Position: 211.16, 7.18 STATUS: LRD_RX_1->signal_level() = -53.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:43: ACU Position: 211.24, 7.2 STATUS: LRD_RX_1->signal_level() = -53.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:44: ACU Position: 211.3, 7.26 STATUS: LRD_RX_1->signal_level() = -54.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:45: ACU Position: 211.37, 7.29 STATUS: LRD_RX_1->signal_level() = -54.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:45: ACU Position: 211.43, 7.31 STATUS: LRD_RX_1->signal_level() = -54.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:46: ACU Position: 211.48, 7.36 STATUS: LRD_RX_1->signal_level() = -53.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:47: ACU Position: 211.54, 7.39 STATUS: LRD_RX_1->signal_level() = -54.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:47: ACU Position: 211.59, 7.43 STATUS: LRD_RX_1->signal_level() = -54.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:48: ACU Position: 211.66, 7.48 STATUS: LRD_RX_1->signal_level() = -54.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:49: ACU Position: 211.73, 7.51 STATUS: LRD_RX_1->signal_level() = -54.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:49: ACU Position: 211.8, 7.55 STATUS: LRD_RX_1->signal_level() = -54.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:28:50: ACU Position: 211.87, 7.59 STATUS: LRD_RX_1->signal_level() = -54.5 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:28:50: ACU Position: 211.93, 7.63 STATUS: LRD_RX_1->signal_level() = -54.7 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:28:51: ACU Position: 212.02, 7.69 STATUS: LRD_RX_1->signal_level() = -54.8 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:28:52: ACU Position: 212.08, 7.71 STATUS: LRD_RX_1->signal_level() = -55.1 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:28:52: ACU Position: 212.15, 7.74 STATUS: LRD_RX_1->signal_level() = -54.7 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:28:53: ACU Position: 212.23, 7.78 STATUS: LRD_RX_1->signal_level() = -55.2 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:28:54: ACU Position: 212.3, 7.84 STATUS: LRD_RX_1->signal_level() = -55.3 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:28:54: ACU Position: 212.38, 7.86 STATUS: LRD_RX_1->signal_level() = -55.2 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:28:55: ACU Position: 212.45, 7.92 STATUS: LRD_RX_1->signal_level() = -55.2 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:28:56: ACU Position: 212.51, 7.96 STATUS: LRD_RX_1->signal_level() = -55.4 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:28:56: ACU Position: 212.58, 7.99 STATUS: LRD_RX_1->signal_level() = -55.3 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:28:57: ACU Position: 212.65, 8.04 STATUS: LRD_RX_1->signal_level() = -55.5 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:28:58: ACU Position: 212.73, 8.07 STATUS: LRD_RX_1->signal_level() = -55.7 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:28:58: ACU Position: 212.8, 8.1 STATUS: LRD_RX_1->signal_level() = -55.8 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:28:59: ACU Position: 212.89, 8.16 STATUS: LRD_RX_1->signal_level() = -55.7 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:29:00: ACU Position: 212.95, 8.19 STATUS: LRD_RX_1->signal_level() = -55.9 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:29:00: ACU Position: 213.02, 8.24 STATUS: LRD_RX_1->signal_level() = -55.7 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:29:01: ACU Position: 213.08, 8.29 STATUS: LRD_RX_1->signal_level() = -55.7 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:29:01: ACU Position: 213.14, 8.31 STATUS: LRD_RX_1->signal_level() = -55.9 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:29:02: ACU Position: 213.21, 8.36 STATUS: LRD_RX_1->signal_level() = -55.9 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:29:03: ACU Position: 213.3, 8.39 STATUS: LRD_RX_1->signal_level() = -55.8 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:29:03: ACU Position: 213.36, 8.43 STATUS: LRD_RX_1->signal_level() = -56.0 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:29:04: ACU Position: 213.44, 8.48 STATUS: LRD_RX_1->signal_level() = -56.1 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:29:05: ACU Position: 213.5, 8.52 STATUS: LRD_RX_1->signal_level() = -55.9 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:29:05: ACU Position: 213.59, 8.55 STATUS: LRD_RX_1->signal_level() = -56.2 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:29:06: ACU Position: 213.66, 8.6 STATUS: LRD_RX_1->signal_level() = -56.2 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:29:07: ACU Position: 213.72, 8.63 STATUS: LRD_RX_1->signal_level() = -56.2 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:29:07: ACU Position: 213.79, 8.66 STATUS: LRD_RX_1->signal_level() = -56.5 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:29:08: ACU Position: 213.85, 8.71 STATUS: LRD_RX_1->signal_level() = -56.3 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:29:08: ACU Position: 213.92, 8.74 STATUS: LRD_RX_1->signal_level() = -56.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:09: ACU Position: 213.99, 8.78 STATUS: LRD_RX_1->signal_level() = -56.3 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:29:10: ACU Position: 214.07, 8.83 STATUS: LRD_RX_1->signal_level() = -56.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:11: ACU Position: 214.14, 8.87 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:11: ACU Position: 214.21, 8.91 STATUS: LRD_RX_1->signal_level() = -56.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:12: ACU Position: 214.3, 8.96 STATUS: LRD_RX_1->signal_level() = -56.6 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:12: ACU Position: 214.38, 8.99 STATUS: LRD_RX_1->signal_level() = -56.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:13: ACU Position: 214.44, 9.04 STATUS: LRD_RX_1->signal_level() = -56.5 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:14: ACU Position: 214.53, 9.09 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:15: ACU Position: 214.63, 9.12 STATUS: LRD_RX_1->signal_level() = -56.6 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:15: ACU Position: 214.7, 9.17 STATUS: LRD_RX_1->signal_level() = -56.6 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:16: ACU Position: 214.78, 9.21 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:17: ACU Position: 214.85, 9.26 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:17: ACU Position: 214.92, 9.3 STATUS: LRD_RX_1->signal_level() = -56.5 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:18: ACU Position: 215.02, 9.32 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:18: ACU Position: 215.08, 9.37 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:19: ACU Position: 215.16, 9.41 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:20: ACU Position: 215.24, 9.45 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:20: ACU Position: 215.3, 9.49 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:21: ACU Position: 215.4, 9.52 STATUS: LRD_RX_1->signal_level() = -56.6 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:22: ACU Position: 215.48, 9.56 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:22: ACU Position: 215.56, 9.61 STATUS: LRD_RX_1->signal_level() = -56.6 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:23: ACU Position: 215.62, 9.63 STATUS: LRD_RX_1->signal_level() = -56.6 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:24: ACU Position: 215.72, 9.7 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:24: ACU Position: 215.79, 9.74 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:25: ACU Position: 215.86, 9.78 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:26: ACU Position: 215.95, 9.82 STATUS: LRD_RX_1->signal_level() = -56.6 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:26: ACU Position: 216.03, 9.85 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:27: ACU Position: 216.09, 9.89 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:28: ACU Position: 216.17, 9.94 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:28: ACU Position: 216.25, 9.98 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:29: ACU Position: 216.31, 10.03 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:29: ACU Position: 216.41, 10.06 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:30: ACU Position: 216.49, 10.1 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:31: ACU Position: 216.56, 10.17 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:31: ACU Position: 216.66, 10.19 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:32: ACU Position: 216.74, 10.22 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:33: ACU Position: 216.82, 10.27 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:33: ACU Position: 216.9, 10.29 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:34: ACU Position: 216.97, 10.36 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:35: ACU Position: 217.08, 10.39 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:35: ACU Position: 217.16, 10.42 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:36: ACU Position: 217.24, 10.47 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:37: ACU Position: 217.33, 10.52 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:37: ACU Position: 217.42, 10.55 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:38: ACU Position: 217.5, 10.61 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:39: ACU Position: 217.58, 10.63 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:39: ACU Position: 217.67, 10.67 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:40: ACU Position: 217.72, 10.72 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:40: ACU Position: 217.83, 10.76 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:41: ACU Position: 217.91, 10.81 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:42: ACU Position: 217.98, 10.85 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:42: ACU Position: 218.06, 10.89 STATUS: LRD_RX_1->signal_level() = -55.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:43: ACU Position: 218.17, 10.93 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:44: ACU Position: 218.25, 10.97 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:44: ACU Position: 218.36, 11.01 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:45: ACU Position: 218.43, 11.06 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:46: ACU Position: 218.51, 11.08 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:46: ACU Position: 218.59, 11.15 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:47: ACU Position: 218.67, 11.17 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:48: ACU Position: 218.74, 11.21 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:48: ACU Position: 218.85, 11.27 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:49: ACU Position: 218.93, 11.3 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:50: ACU Position: 219.01, 11.33 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:50: ACU Position: 219.09, 11.39 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:51: ACU Position: 219.18, 11.42 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:51: ACU Position: 219.29, 11.47 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:52: ACU Position: 219.38, 11.51 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:53: ACU Position: 219.45, 11.55 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:54: ACU Position: 219.57, 11.59 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:54: ACU Position: 219.64, 11.63 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:55: ACU Position: 219.73, 11.68 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:55: ACU Position: 219.84, 11.72 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:56: ACU Position: 219.93, 11.75 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:57: ACU Position: 220.02, 11.79 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:57: ACU Position: 220.13, 11.86 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:58: ACU Position: 220.21, 11.88 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:59: ACU Position: 220.3, 11.94 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:29:59: ACU Position: 220.38, 11.97 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:00: ACU Position: 220.47, 12.03 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:01: ACU Position: 220.58, 12.06 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:01: ACU Position: 220.67, 12.08 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:02: ACU Position: 220.74, 12.14 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:03: ACU Position: 220.86, 12.19 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:03: ACU Position: 220.94, 12.22 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:04: ACU Position: 221.03, 12.27 STATUS: LRD_RX_1->signal_level() = -56.6 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:05: ACU Position: 221.15, 12.31 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:05: ACU Position: 221.21, 12.37 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:06: ACU Position: 221.3, 12.4 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:07: ACU Position: 221.39, 12.43 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:07: ACU Position: 221.48, 12.49 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:08: ACU Position: 221.6, 12.52 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:09: ACU Position: 221.69, 12.55 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:09: ACU Position: 221.77, 12.62 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:10: ACU Position: 221.87, 12.64 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:10: ACU Position: 221.98, 12.68 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:11: ACU Position: 222.08, 12.73 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:12: ACU Position: 222.17, 12.76 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:12: ACU Position: 222.27, 12.82 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:13: ACU Position: 222.39, 12.86 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:14: ACU Position: 222.48, 12.9 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:15: ACU Position: 222.6, 12.94 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:15: ACU Position: 222.69, 12.97 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:16: ACU Position: 222.79, 13.04 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:16: ACU Position: 222.86, 13.07 STATUS: LRD_RX_1->signal_level() = -56.6 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:17: ACU Position: 222.99, 13.11 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:18: ACU Position: 223.07, 13.15 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:18: ACU Position: 223.16, 13.19 STATUS: LRD_RX_1->signal_level() = -56.4 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:19: ACU Position: 223.28, 13.23 STATUS: LRD_RX_1->signal_level() = -56.6 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:20: ACU Position: 223.37, 13.28 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:20: ACU Position: 223.47, 13.31 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:21: ACU Position: 223.55, 13.35 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:22: ACU Position: 223.64, 13.41 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:22: ACU Position: 223.76, 13.44 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:23: ACU Position: 223.86, 13.5 STATUS: LRD_RX_1->signal_level() = -56.6 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:24: ACU Position: 223.99, 13.53 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:24: ACU Position: 224.08, 13.56 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:25: ACU Position: 224.19, 13.62 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:26: ACU Position: 224.28, 13.64 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:26: ACU Position: 224.38, 13.7 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:27: ACU Position: 224.48, 13.74 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:28: ACU Position: 224.6, 13.77 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:28: ACU Position: 224.71, 13.84 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:29: ACU Position: 224.83, 13.86 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:30: ACU Position: 224.93, 13.9 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:30: ACU Position: 225.03, 13.96 STATUS: LRD_RX_1->signal_level() = -56.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:31: ACU Position: 225.15, 13.99 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:32: ACU Position: 225.24, 14.02 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:32: ACU Position: 225.33, 14.1 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:33: ACU Position: 225.46, 14.11 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:34: ACU Position: 225.55, 14.17 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:34: ACU Position: 225.65, 14.2 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:35: ACU Position: 225.75, 14.24 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:36: ACU Position: 225.85, 14.28 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:36: ACU Position: 225.97, 14.32 STATUS: LRD_RX_1->signal_level() = -56.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:37: ACU Position: 226.07, 14.37 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:38: ACU Position: 226.17, 14.4 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:38: ACU Position: 226.31, 14.45 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:39: ACU Position: 226.41, 14.49 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:40: ACU Position: 226.55, 14.53 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:40: ACU Position: 226.65, 14.57 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:41: ACU Position: 226.76, 14.63 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:41: ACU Position: 226.86, 14.66 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:42: ACU Position: 226.97, 14.71 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:43: ACU Position: 227.1, 14.74 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:44: ACU Position: 227.2, 14.79 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:44: ACU Position: 227.31, 14.83 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:45: ACU Position: 227.42, 14.88 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:45: ACU Position: 227.53, 14.9 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:46: ACU Position: 227.63, 14.96 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:47: ACU Position: 227.74, 14.98 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:47: ACU Position: 227.87, 15.04 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:48: ACU Position: 227.97, 15.09 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:49: ACU Position: 228.11, 15.11 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:49: ACU Position: 228.21, 15.17 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:50: ACU Position: 228.31, 15.2 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:51: ACU Position: 228.42, 15.24 STATUS: LRD_RX_1->signal_level() = -57.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:51: ACU Position: 228.56, 15.29 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:52: ACU Position: 228.71, 15.33 STATUS: LRD_RX_1->signal_level() = -57.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:53: ACU Position: 228.82, 15.37 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:53: ACU Position: 228.93, 15.41 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:54: ACU Position: 229.03, 15.44 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:55: ACU Position: 229.14, 15.5 STATUS: LRD_RX_1->signal_level() = -56.5 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:55: ACU Position: 229.29, 15.54 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:56: ACU Position: 229.4, 15.56 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:57: ACU Position: 229.51, 15.61 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:57: ACU Position: 229.6, 15.63 STATUS: LRD_RX_1->signal_level() = -56.4 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:58: ACU Position: 229.71, 15.68 STATUS: LRD_RX_1->signal_level() = -56.5 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:59: ACU Position: 229.82, 15.73 STATUS: LRD_RX_1->signal_level() = -56.4 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:30:59: ACU Position: 229.96, 15.76 STATUS: LRD_RX_1->signal_level() = -57.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:00: ACU Position: 230.07, 15.8 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:01: ACU Position: 230.18, 15.84 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:01: ACU Position: 230.29, 15.88 STATUS: LRD_RX_1->signal_level() = -56.4 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:02: ACU Position: 230.43, 15.94 STATUS: LRD_RX_1->signal_level() = -56.6 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:03: ACU Position: 230.54, 15.97 STATUS: LRD_RX_1->signal_level() = -56.6 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:03: ACU Position: 230.65, 16 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:04: ACU Position: 230.76, 16.06 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:04: ACU Position: 230.9, 16.08 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:05: ACU Position: 231.01, 16.11 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:06: ACU Position: 231.17, 16.18 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:06: ACU Position: 231.28, 16.2 STATUS: LRD_RX_1->signal_level() = -57.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:07: ACU Position: 231.4, 16.24 STATUS: LRD_RX_1->signal_level() = -57.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:08: ACU Position: 231.51, 16.3 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:08: ACU Position: 231.66, 16.31 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:09: ACU Position: 231.77, 16.36 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:10: ACU Position: 231.89, 16.43 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:10: ACU Position: 232.05, 16.44 STATUS: LRD_RX_1->signal_level() = -56.6 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:11: ACU Position: 232.16, 16.47 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:12: ACU Position: 232.26, 16.53 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:12: ACU Position: 232.41, 16.56 STATUS: LRD_RX_1->signal_level() = -57.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:13: ACU Position: 232.52, 16.61 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:14: ACU Position: 232.67, 16.65 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:15: ACU Position: 232.79, 16.68 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:15: ACU Position: 232.91, 16.74 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:16: ACU Position: 233.02, 16.76 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:16: ACU Position: 233.18, 16.8 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:17: ACU Position: 233.3, 16.86 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:18: ACU Position: 233.44, 16.87 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:19: ACU Position: 233.56, 16.93 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:19: ACU Position: 233.68, 16.98 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:20: ACU Position: 233.84, 16.99 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:20: ACU Position: 233.96, 17.05 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:21: ACU Position: 234.08, 17.09 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:22: ACU Position: 234.24, 17.11 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:23: ACU Position: 234.37, 17.16 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:23: ACU Position: 234.49, 17.19 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:24: ACU Position: 234.61, 17.23 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:24: ACU Position: 234.75, 17.27 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:25: ACU Position: 234.87, 17.32 STATUS: LRD_RX_1->signal_level() = -54.6 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:26: ACU Position: 234.99, 17.34 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:26: ACU Position: 235.15, 17.39 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:27: ACU Position: 235.28, 17.42 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:28: ACU Position: 235.4, 17.44 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:28: ACU Position: 235.51, 17.49 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:29: ACU Position: 235.64, 17.53 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:30: ACU Position: 235.76, 17.56 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:30: ACU Position: 235.91, 17.6 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:31: ACU Position: 236.04, 17.64 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:32: ACU Position: 236.2, 17.67 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:32: ACU Position: 236.32, 17.71 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:33: ACU Position: 236.44, 17.74 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:34: ACU Position: 236.57, 17.78 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:34: ACU Position: 236.74, 17.82 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:35: ACU Position: 236.87, 17.85 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:36: ACU Position: 237, 17.88 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:36: ACU Position: 237.12, 17.93 STATUS: LRD_RX_1->signal_level() = -56.4 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:37: ACU Position: 237.23, 17.97 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:37: ACU Position: 237.4, 17.99 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:38: ACU Position: 237.53, 18.02 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:39: ACU Position: 237.65, 18.06 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:39: ACU Position: 237.78, 18.1 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:40: ACU Position: 237.95, 18.14 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:41: ACU Position: 238.08, 18.19 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:41: ACU Position: 238.21, 18.21 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:42: ACU Position: 238.38, 18.24 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:43: ACU Position: 238.5, 18.29 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:43: ACU Position: 238.63, 18.32 STATUS: LRD_RX_1->signal_level() = -57.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:44: ACU Position: 238.8, 18.34 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:45: ACU Position: 238.92, 18.38 STATUS: LRD_RX_1->signal_level() = -56.4 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:45: ACU Position: 239.06, 18.42 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:46: ACU Position: 239.18, 18.45 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:47: ACU Position: 239.31, 18.49 STATUS: LRD_RX_1->signal_level() = -56.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:47: ACU Position: 239.48, 18.52 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:48: ACU Position: 239.66, 18.55 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:49: ACU Position: 239.8, 18.58 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:49: ACU Position: 239.92, 18.63 STATUS: LRD_RX_1->signal_level() = -56.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:50: ACU Position: 240.07, 18.65 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:51: ACU Position: 240.18, 18.69 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:51: ACU Position: 240.35, 18.73 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:52: ACU Position: 240.48, 18.76 STATUS: LRD_RX_1->signal_level() = -56.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:53: ACU Position: 240.62, 18.78 STATUS: LRD_RX_1->signal_level() = -56.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:53: ACU Position: 240.75, 18.81 STATUS: LRD_RX_1->signal_level() = -56.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:54: ACU Position: 240.89, 18.86 STATUS: LRD_RX_1->signal_level() = -56.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:55: ACU Position: 241.07, 18.88 STATUS: LRD_RX_1->signal_level() = -56.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:55: ACU Position: 241.2, 18.91 STATUS: LRD_RX_1->signal_level() = -56.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:56: ACU Position: 241.33, 18.95 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:56: ACU Position: 241.46, 18.98 STATUS: LRD_RX_1->signal_level() = -55.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:57: ACU Position: 241.64, 19 STATUS: LRD_RX_1->signal_level() = -55.4 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:58: ACU Position: 241.77, 19.03 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:58: ACU Position: 241.9, 19.07 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:31:59: ACU Position: 242.04, 19.1 STATUS: LRD_RX_1->signal_level() = -56.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:00: ACU Position: 242.17, 19.13 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:00: ACU Position: 242.35, 19.16 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:01: ACU Position: 242.48, 19.2 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:02: ACU Position: 242.63, 19.22 STATUS: LRD_RX_1->signal_level() = -56.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:02: ACU Position: 242.77, 19.25 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:03: ACU Position: 242.96, 19.29 STATUS: LRD_RX_1->signal_level() = -56.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:04: ACU Position: 243.07, 19.31 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:04: ACU Position: 243.21, 19.33 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:05: ACU Position: 243.38, 19.38 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:06: ACU Position: 243.53, 19.42 STATUS: LRD_RX_1->signal_level() = -55.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:06: ACU Position: 243.67, 19.43 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:07: ACU Position: 243.81, 19.46 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:08: ACU Position: 243.95, 19.49 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:08: ACU Position: 244.13, 19.53 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:09: ACU Position: 244.27, 19.54 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:09: ACU Position: 244.42, 19.58 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:10: ACU Position: 244.56, 19.62 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:11: ACU Position: 244.75, 19.65 STATUS: LRD_RX_1->signal_level() = -55.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:11: ACU Position: 244.88, 19.66 STATUS: LRD_RX_1->signal_level() = -55.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:12: ACU Position: 245.01, 19.69 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:13: ACU Position: 245.15, 19.74 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:14: ACU Position: 245.34, 19.77 STATUS: LRD_RX_1->signal_level() = -56.6 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:14: ACU Position: 245.53, 19.79 STATUS: LRD_RX_1->signal_level() = -56.4 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:15: ACU Position: 245.71, 19.81 STATUS: LRD_RX_1->signal_level() = -56.4 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:16: ACU Position: 245.83, 19.85 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:16: ACU Position: 245.98, 19.87 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:17: ACU Position: 246.12, 19.9 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:18: ACU Position: 246.31, 19.94 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:18: ACU Position: 246.46, 19.97 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:19: ACU Position: 246.65, 19.98 STATUS: LRD_RX_1->signal_level() = -56.4 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:20: ACU Position: 246.79, 20 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:20: ACU Position: 246.93, 20.03 STATUS: LRD_RX_1->signal_level() = -55.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:21: ACU Position: 247.13, 20.07 STATUS: LRD_RX_1->signal_level() = -55.6 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:22: ACU Position: 247.27, 20.09 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:22: ACU Position: 247.43, 20.11 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:23: ACU Position: 247.61, 20.14 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:24: ACU Position: 247.76, 20.17 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:24: ACU Position: 247.91, 20.2 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:25: ACU Position: 248.1, 20.21 STATUS: LRD_RX_1->signal_level() = -55.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:26: ACU Position: 248.25, 20.23 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:26: ACU Position: 248.39, 20.27 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:27: ACU Position: 248.59, 20.3 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:28: ACU Position: 248.74, 20.31 STATUS: LRD_RX_1->signal_level() = -55.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:28: ACU Position: 248.88, 20.34 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:29: ACU Position: 249.06, 20.37 STATUS: LRD_RX_1->signal_level() = -55.6 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:30: ACU Position: 249.22, 20.4 STATUS: LRD_RX_1->signal_level() = -56.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:30: ACU Position: 249.34, 20.41 STATUS: LRD_RX_1->signal_level() = -55.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:31: ACU Position: 249.48, 20.43 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:32: ACU Position: 249.68, 20.46 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:32: ACU Position: 249.82, 20.48 STATUS: LRD_RX_1->signal_level() = -55.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:33: ACU Position: 249.97, 20.51 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:34: ACU Position: 250.16, 20.53 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:34: ACU Position: 250.32, 20.55 STATUS: LRD_RX_1->signal_level() = -55.6 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:35: ACU Position: 250.46, 20.58 STATUS: LRD_RX_1->signal_level() = -56.5 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:36: ACU Position: 250.67, 20.61 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:36: ACU Position: 250.81, 20.61 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:37: ACU Position: 250.97, 20.64 STATUS: LRD_RX_1->signal_level() = -56.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:38: ACU Position: 251.12, 20.65 STATUS: LRD_RX_1->signal_level() = -55.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:38: ACU Position: 251.27, 20.68 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:39: ACU Position: 251.43, 20.7 STATUS: LRD_RX_1->signal_level() = -56.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:39: ACU Position: 251.62, 20.73 STATUS: LRD_RX_1->signal_level() = -57.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:40: ACU Position: 251.78, 20.74 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:41: ACU Position: 251.93, 20.76 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:41: ACU Position: 252.09, 20.77 STATUS: LRD_RX_1->signal_level() = -56.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:42: ACU Position: 252.23, 20.79 STATUS: LRD_RX_1->signal_level() = -56.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:43: ACU Position: 252.44, 20.81 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:43: ACU Position: 252.56, 20.84 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:44: ACU Position: 252.71, 20.86 STATUS: LRD_RX_1->signal_level() = -57.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:45: ACU Position: 252.87, 20.88 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:45: ACU Position: 253.06, 20.88 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:46: ACU Position: 253.22, 20.9 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:47: ACU Position: 253.42, 20.92 STATUS: LRD_RX_1->signal_level() = -57.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:47: ACU Position: 253.57, 20.95 STATUS: LRD_RX_1->signal_level() = -56.6 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:48: ACU Position: 253.72, 20.96 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:49: ACU Position: 253.88, 20.99 STATUS: LRD_RX_1->signal_level() = -56.4 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:49: ACU Position: 254.07, 20.99 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:50: ACU Position: 254.23, 21.01 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:51: ACU Position: 254.43, 21.03 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:51: ACU Position: 254.58, 21.05 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:52: ACU Position: 254.78, 21.08 STATUS: LRD_RX_1->signal_level() = -57.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:53: ACU Position: 254.93, 21.08 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:53: ACU Position: 255.09, 21.09 STATUS: LRD_RX_1->signal_level() = -56.5 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:54: ACU Position: 255.28, 21.11 STATUS: LRD_RX_1->signal_level() = -55.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:55: ACU Position: 255.44, 21.13 STATUS: LRD_RX_1->signal_level() = -56.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:55: ACU Position: 255.59, 21.16 STATUS: LRD_RX_1->signal_level() = -56.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:56: ACU Position: 255.71, 21.16 STATUS: LRD_RX_1->signal_level() = -57.4 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:57: ACU Position: 255.92, 21.18 STATUS: LRD_RX_1->signal_level() = -57.4 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:57: ACU Position: 256.07, 21.19 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:58: ACU Position: 256.23, 21.21 STATUS: LRD_RX_1->signal_level() = -56.4 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:59: ACU Position: 256.39, 21.21 STATUS: LRD_RX_1->signal_level() = -56.6 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:32:59: ACU Position: 256.6, 21.23 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:00: ACU Position: 256.76, 21.23 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:01: ACU Position: 256.92, 21.25 STATUS: LRD_RX_1->signal_level() = -57.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:01: ACU Position: 257.07, 21.28 STATUS: LRD_RX_1->signal_level() = -56.6 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:02: ACU Position: 257.28, 21.28 STATUS: LRD_RX_1->signal_level() = -56.6 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:03: ACU Position: 257.45, 21.3 STATUS: LRD_RX_1->signal_level() = -56.5 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:03: ACU Position: 257.6, 21.3 STATUS: LRD_RX_1->signal_level() = -56.5 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:04: ACU Position: 257.75, 21.32 STATUS: LRD_RX_1->signal_level() = -56.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:04: ACU Position: 257.96, 21.32 STATUS: LRD_RX_1->signal_level() = -57.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:05: ACU Position: 258.13, 21.34 STATUS: LRD_RX_1->signal_level() = -53.4 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:06: ACU Position: 258.34, 21.34 STATUS: LRD_RX_1->signal_level() = -57.4 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:07: ACU Position: 258.49, 21.35 STATUS: LRD_RX_1->signal_level() = -56.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:07: ACU Position: 258.66, 21.37 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:08: ACU Position: 258.81, 21.37 STATUS: LRD_RX_1->signal_level() = -56.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:08: ACU Position: 258.96, 21.4 STATUS: LRD_RX_1->signal_level() = -57.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:09: ACU Position: 259.15, 21.4 STATUS: LRD_RX_1->signal_level() = -56.6 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:10: ACU Position: 259.3, 21.41 STATUS: LRD_RX_1->signal_level() = -56.6 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:10: ACU Position: 259.47, 21.42 STATUS: LRD_RX_1->signal_level() = -56.4 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:11: ACU Position: 259.62, 21.44 STATUS: LRD_RX_1->signal_level() = -57.6 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:12: ACU Position: 259.83, 21.44 STATUS: LRD_RX_1->signal_level() = -57.4 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:12: ACU Position: 259.99, 21.44 STATUS: LRD_RX_1->signal_level() = -56.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:13: ACU Position: 260.14, 21.44 STATUS: LRD_RX_1->signal_level() = -56.4 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:14: ACU Position: 260.36, 21.46 STATUS: LRD_RX_1->signal_level() = -57.5 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:14: ACU Position: 260.51, 21.46 STATUS: LRD_RX_1->signal_level() = -57.5 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:15: ACU Position: 260.67, 21.47 STATUS: LRD_RX_1->signal_level() = -55.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:16: ACU Position: 260.89, 21.48 STATUS: LRD_RX_1->signal_level() = -56.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:16: ACU Position: 261.04, 21.48 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:17: ACU Position: 261.19, 21.51 STATUS: LRD_RX_1->signal_level() = -57.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:18: ACU Position: 261.35, 21.51 STATUS: LRD_RX_1->signal_level() = -56.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:18: ACU Position: 261.57, 21.51 STATUS: LRD_RX_1->signal_level() = -56.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:19: ACU Position: 261.72, 21.52 STATUS: LRD_RX_1->signal_level() = -56.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:20: ACU Position: 261.87, 21.53 STATUS: LRD_RX_1->signal_level() = -57.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:20: ACU Position: 262.08, 21.54 STATUS: LRD_RX_1->signal_level() = -57.5 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:21: ACU Position: 262.24, 21.54 STATUS: LRD_RX_1->signal_level() = -55.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:22: ACU Position: 262.4, 21.54 STATUS: LRD_RX_1->signal_level() = -55.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:22: ACU Position: 262.53, 21.54 STATUS: LRD_RX_1->signal_level() = -55.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:23: ACU Position: 262.74, 21.54 STATUS: LRD_RX_1->signal_level() = -57.5 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:24: ACU Position: 262.9, 21.54 STATUS: LRD_RX_1->signal_level() = -56.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:24: ACU Position: 263.06, 21.56 STATUS: LRD_RX_1->signal_level() = -55.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:25: ACU Position: 263.22, 21.56 STATUS: LRD_RX_1->signal_level() = -56.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:26: ACU Position: 263.42, 21.56 STATUS: LRD_RX_1->signal_level() = -55.5 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:26: ACU Position: 263.59, 21.56 STATUS: LRD_RX_1->signal_level() = -55.9 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:27: ACU Position: 263.74, 21.56 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:28: ACU Position: 263.95, 21.56 STATUS: LRD_RX_1->signal_level() = -57.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:28: ACU Position: 264.11, 21.58 STATUS: LRD_RX_1->signal_level() = -57.5 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:29: ACU Position: 264.31, 21.58 STATUS: LRD_RX_1->signal_level() = -55.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:30: ACU Position: 264.48, 21.58 STATUS: LRD_RX_1->signal_level() = -55.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:30: ACU Position: 264.63, 21.58 STATUS: LRD_RX_1->signal_level() = -56.6 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:31: ACU Position: 264.8, 21.58 STATUS: LRD_RX_1->signal_level() = -57.4 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:32: ACU Position: 264.95, 21.58 STATUS: LRD_RX_1->signal_level() = -57.4 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:32: ACU Position: 265.1, 21.58 STATUS: LRD_RX_1->signal_level() = -55.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:33: ACU Position: 265.31, 21.58 STATUS: LRD_RX_1->signal_level() = -57.4 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:34: ACU Position: 265.52, 21.58 STATUS: LRD_RX_1->signal_level() = -55.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:34: ACU Position: 265.69, 21.58 STATUS: LRD_RX_1->signal_level() = -55.4 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:35: ACU Position: 265.84, 21.58 STATUS: LRD_RX_1->signal_level() = -57.5 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:35: ACU Position: 266.01, 21.58 STATUS: LRD_RX_1->signal_level() = -57.5 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:36: ACU Position: 266.18, 21.58 STATUS: LRD_RX_1->signal_level() = -57.5 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:37: ACU Position: 266.34, 21.58 STATUS: LRD_RX_1->signal_level() = -55.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:38: ACU Position: 266.5, 21.58 STATUS: LRD_RX_1->signal_level() = -57.4 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:38: ACU Position: 266.71, 21.58 STATUS: LRD_RX_1->signal_level() = -55.4 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:39: ACU Position: 266.86, 21.58 STATUS: LRD_RX_1->signal_level() = -55.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:40: ACU Position: 267.07, 21.58 STATUS: LRD_RX_1->signal_level() = -57.4 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:40: ACU Position: 267.24, 21.58 STATUS: LRD_RX_1->signal_level() = -55.6 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:41: ACU Position: 267.39, 21.58 STATUS: LRD_RX_1->signal_level() = -57.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:42: ACU Position: 267.54, 21.58 STATUS: LRD_RX_1->signal_level() = -55.4 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:42: ACU Position: 267.76, 21.58 STATUS: LRD_RX_1->signal_level() = -54.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:43: ACU Position: 267.92, 21.57 STATUS: LRD_RX_1->signal_level() = -56.5 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:44: ACU Position: 268.07, 21.57 STATUS: LRD_RX_1->signal_level() = -55.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:44: ACU Position: 268.28, 21.55 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:45: ACU Position: 268.44, 21.55 STATUS: LRD_RX_1->signal_level() = -57.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:45: ACU Position: 268.6, 21.55 STATUS: LRD_RX_1->signal_level() = -54.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:46: ACU Position: 268.75, 21.55 STATUS: LRD_RX_1->signal_level() = -57.1 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:47: ACU Position: 268.91, 21.55 STATUS: LRD_RX_1->signal_level() = -55.5 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:47: ACU Position: 269.11, 21.55 STATUS: LRD_RX_1->signal_level() = -55.4 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:48: ACU Position: 269.25, 21.54 STATUS: LRD_RX_1->signal_level() = -54.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:49: ACU Position: 269.4, 21.53 STATUS: LRD_RX_1->signal_level() = -57.0 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:49: ACU Position: 269.57, 21.53 STATUS: LRD_RX_1->signal_level() = -55.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:50: ACU Position: 269.77, 21.53 STATUS: LRD_RX_1->signal_level() = -54.7 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:51: ACU Position: 269.93, 21.52 STATUS: LRD_RX_1->signal_level() = -55.3 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:51: ACU Position: 270.09, 21.5 STATUS: LRD_RX_1->signal_level() = -55.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:52: ACU Position: 270.25, 21.5 STATUS: LRD_RX_1->signal_level() = -55.2 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:53: ACU Position: 270.46, 21.5 STATUS: LRD_RX_1->signal_level() = -56.8 STATUS: LRD_RX_1->lock_status() = UL STATUS: 16-Jun-2025 03:33:53: ACU Position: 270.62, 21.48 STATUS: LRD_RX_1->signal_level() = -56.6 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:33:54: ACU Position: 270.77, 21.47 STATUS: LRD_RX_1->signal_level() = -56.2 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:33:55: ACU Position: 270.94, 21.47 STATUS: LRD_RX_1->signal_level() = -56.5 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:33:55: ACU Position: 271.15, 21.46 STATUS: LRD_RX_1->signal_level() = -56.1 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:33:56: ACU Position: 271.3, 21.44 STATUS: LRD_RX_1->signal_level() = -54.9 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:33:56: ACU Position: 271.45, 21.44 STATUS: LRD_RX_1->signal_level() = -56.2 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:33:57: ACU Position: 271.62, 21.44 STATUS: LRD_RX_1->signal_level() = -53.6 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:33:58: ACU Position: 271.83, 21.44 STATUS: LRD_RX_1->signal_level() = -55.7 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:33:58: ACU Position: 271.98, 21.42 STATUS: LRD_RX_1->signal_level() = -55.2 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:33:59: ACU Position: 272.14, 21.42 STATUS: LRD_RX_1->signal_level() = -55.1 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:34:00: ACU Position: 272.3, 21.4 STATUS: LRD_RX_1->signal_level() = -54.1 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:34:00: ACU Position: 272.51, 21.39 STATUS: LRD_RX_1->signal_level() = -52.8 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:34:01: ACU Position: 272.66, 21.37 STATUS: LRD_RX_1->signal_level() = -52.2 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:34:02: ACU Position: 272.82, 21.36 STATUS: LRD_RX_1->signal_level() = -51.6 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:34:02: ACU Position: 272.95, 21.35 STATUS: LRD_RX_1->signal_level() = -52.6 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:34:03: ACU Position: 273.16, 21.33 STATUS: LRD_RX_1->signal_level() = -51.2 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:34:04: ACU Position: 273.32, 21.33 STATUS: LRD_RX_1->signal_level() = -51.1 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:34:04: ACU Position: 273.48, 21.33 STATUS: LRD_RX_1->signal_level() = -49.7 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:34:05: ACU Position: 273.69, 21.31 STATUS: LRD_RX_1->signal_level() = -50.2 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:34:06: ACU Position: 273.84, 21.3 STATUS: LRD_RX_1->signal_level() = -49.5 STATUS: LRD_RX_1->lock_status() = LK STATUS: 16-Jun-2025 03:34:06: ACU Position: 273.99, 21.29 STATUS: LRD_RX_1->signal_level() = -48.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:07: ACU Position: 274.16, 21.28 STATUS: LRD_RX_1->signal_level() = -48.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:08: ACU Position: 274.31, 21.25 STATUS: LRD_RX_1->signal_level() = -47.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:08: ACU Position: 274.51, 21.24 STATUS: LRD_RX_1->signal_level() = -46.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:09: ACU Position: 274.66, 21.23 STATUS: LRD_RX_1->signal_level() = -46.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:10: ACU Position: 274.82, 21.22 STATUS: LRD_RX_1->signal_level() = -45.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:10: ACU Position: 274.97, 21.21 STATUS: LRD_RX_1->signal_level() = -45.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:11: ACU Position: 275.18, 21.19 STATUS: LRD_RX_1->signal_level() = -45.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:11: ACU Position: 275.32, 21.19 STATUS: LRD_RX_1->signal_level() = -44.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:12: ACU Position: 275.48, 21.17 STATUS: LRD_RX_1->signal_level() = -43.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:13: ACU Position: 275.67, 21.14 STATUS: LRD_RX_1->signal_level() = -43.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:14: ACU Position: 275.83, 21.12 STATUS: LRD_RX_1->signal_level() = -43.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:14: ACU Position: 276.03, 21.11 STATUS: LRD_RX_1->signal_level() = -42.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:15: ACU Position: 276.18, 21.1 STATUS: LRD_RX_1->signal_level() = -42.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:16: ACU Position: 276.3, 21.1 STATUS: LRD_RX_1->signal_level() = -41.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:16: ACU Position: 276.45, 21.08 STATUS: LRD_RX_1->signal_level() = -41.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:17: ACU Position: 276.61, 21.06 STATUS: LRD_RX_1->signal_level() = -41.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:17: ACU Position: 276.81, 21.03 STATUS: LRD_RX_1->signal_level() = -40.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:18: ACU Position: 276.96, 21.02 STATUS: LRD_RX_1->signal_level() = -40.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:19: ACU Position: 277.11, 21 STATUS: LRD_RX_1->signal_level() = -40.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:19: ACU Position: 277.27, 20.99 STATUS: LRD_RX_1->signal_level() = -40.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:20: ACU Position: 277.46, 20.97 STATUS: LRD_RX_1->signal_level() = -39.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:21: ACU Position: 277.62, 20.95 STATUS: LRD_RX_1->signal_level() = -39.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:21: ACU Position: 277.77, 20.94 STATUS: LRD_RX_1->signal_level() = -39.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:22: ACU Position: 277.97, 20.91 STATUS: LRD_RX_1->signal_level() = -38.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:23: ACU Position: 278.12, 20.9 STATUS: LRD_RX_1->signal_level() = -39.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:23: ACU Position: 278.28, 20.89 STATUS: LRD_RX_1->signal_level() = -38.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:24: ACU Position: 278.43, 20.86 STATUS: LRD_RX_1->signal_level() = -38.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:25: ACU Position: 278.63, 20.85 STATUS: LRD_RX_1->signal_level() = -38.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:25: ACU Position: 278.78, 20.83 STATUS: LRD_RX_1->signal_level() = -38.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:26: ACU Position: 278.93, 20.8 STATUS: LRD_RX_1->signal_level() = -38.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:27: ACU Position: 279.08, 20.78 STATUS: LRD_RX_1->signal_level() = -38.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:27: ACU Position: 279.23, 20.77 STATUS: LRD_RX_1->signal_level() = -38.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:28: ACU Position: 279.41, 20.75 STATUS: LRD_RX_1->signal_level() = -37.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:29: ACU Position: 279.56, 20.73 STATUS: LRD_RX_1->signal_level() = -37.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:29: ACU Position: 279.72, 20.7 STATUS: LRD_RX_1->signal_level() = -37.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:30: ACU Position: 279.87, 20.69 STATUS: LRD_RX_1->signal_level() = -37.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:30: ACU Position: 280.01, 20.67 STATUS: LRD_RX_1->signal_level() = -37.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:31: ACU Position: 280.22, 20.65 STATUS: LRD_RX_1->signal_level() = -37.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:32: ACU Position: 280.36, 20.62 STATUS: LRD_RX_1->signal_level() = -37.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:32: ACU Position: 280.51, 20.61 STATUS: LRD_RX_1->signal_level() = -38.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:33: ACU Position: 280.69, 20.58 STATUS: LRD_RX_1->signal_level() = -37.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:34: ACU Position: 280.85, 20.56 STATUS: LRD_RX_1->signal_level() = -37.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:34: ACU Position: 280.99, 20.54 STATUS: LRD_RX_1->signal_level() = -38.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:35: ACU Position: 281.18, 20.51 STATUS: LRD_RX_1->signal_level() = -38.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:36: ACU Position: 281.38, 20.48 STATUS: LRD_RX_1->signal_level() = -37.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:37: ACU Position: 281.52, 20.46 STATUS: LRD_RX_1->signal_level() = -37.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:37: ACU Position: 281.67, 20.44 STATUS: LRD_RX_1->signal_level() = -38.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:38: ACU Position: 281.82, 20.42 STATUS: LRD_RX_1->signal_level() = -37.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:38: ACU Position: 281.96, 20.4 STATUS: LRD_RX_1->signal_level() = -37.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:39: ACU Position: 282.16, 20.37 STATUS: LRD_RX_1->signal_level() = -37.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:40: ACU Position: 282.3, 20.35 STATUS: LRD_RX_1->signal_level() = -38.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:40: ACU Position: 282.44, 20.33 STATUS: LRD_RX_1->signal_level() = -38.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:41: ACU Position: 282.58, 20.31 STATUS: LRD_RX_1->signal_level() = -38.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:42: ACU Position: 282.78, 20.28 STATUS: LRD_RX_1->signal_level() = -38.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:42: ACU Position: 282.9, 20.25 STATUS: LRD_RX_1->signal_level() = -38.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:43: ACU Position: 283.06, 20.22 STATUS: LRD_RX_1->signal_level() = -38.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:44: ACU Position: 283.2, 20.21 STATUS: LRD_RX_1->signal_level() = -38.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:44: ACU Position: 283.39, 20.18 STATUS: LRD_RX_1->signal_level() = -37.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:45: ACU Position: 283.53, 20.14 STATUS: LRD_RX_1->signal_level() = -37.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:46: ACU Position: 283.67, 20.12 STATUS: LRD_RX_1->signal_level() = -37.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:46: ACU Position: 283.83, 20.11 STATUS: LRD_RX_1->signal_level() = -37.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:47: ACU Position: 284.01, 20.08 STATUS: LRD_RX_1->signal_level() = -37.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:48: ACU Position: 284.17, 20.06 STATUS: LRD_RX_1->signal_level() = -37.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:48: ACU Position: 284.31, 20.03 STATUS: LRD_RX_1->signal_level() = -38.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:49: ACU Position: 284.45, 20 STATUS: LRD_RX_1->signal_level() = -38.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:50: ACU Position: 284.65, 19.97 STATUS: LRD_RX_1->signal_level() = -37.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:50: ACU Position: 284.78, 19.95 STATUS: LRD_RX_1->signal_level() = -37.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:51: ACU Position: 284.92, 19.91 STATUS: LRD_RX_1->signal_level() = -37.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:51: ACU Position: 285.06, 19.9 STATUS: LRD_RX_1->signal_level() = -38.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:52: ACU Position: 285.2, 19.87 STATUS: LRD_RX_1->signal_level() = -37.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:53: ACU Position: 285.34, 19.84 STATUS: LRD_RX_1->signal_level() = -37.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:53: ACU Position: 285.53, 19.83 STATUS: LRD_RX_1->signal_level() = -37.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:54: ACU Position: 285.67, 19.79 STATUS: LRD_RX_1->signal_level() = -37.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:55: ACU Position: 285.83, 19.76 STATUS: LRD_RX_1->signal_level() = -37.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:55: ACU Position: 285.97, 19.74 STATUS: LRD_RX_1->signal_level() = -37.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:56: ACU Position: 286.1, 19.69 STATUS: LRD_RX_1->signal_level() = -37.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:57: ACU Position: 286.29, 19.67 STATUS: LRD_RX_1->signal_level() = -37.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:57: ACU Position: 286.43, 19.65 STATUS: LRD_RX_1->signal_level() = -37.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:58: ACU Position: 286.57, 19.62 STATUS: LRD_RX_1->signal_level() = -37.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:59: ACU Position: 286.71, 19.58 STATUS: LRD_RX_1->signal_level() = -37.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:34:59: ACU Position: 286.85, 19.55 STATUS: LRD_RX_1->signal_level() = -37.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:00: ACU Position: 287.03, 19.54 STATUS: LRD_RX_1->signal_level() = -37.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:01: ACU Position: 287.18, 19.51 STATUS: LRD_RX_1->signal_level() = -37.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:01: ACU Position: 287.32, 19.46 STATUS: LRD_RX_1->signal_level() = -37.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:02: ACU Position: 287.49, 19.43 STATUS: LRD_RX_1->signal_level() = -37.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:03: ACU Position: 287.64, 19.42 STATUS: LRD_RX_1->signal_level() = -37.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:03: ACU Position: 287.78, 19.39 STATUS: LRD_RX_1->signal_level() = -37.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:04: ACU Position: 287.91, 19.35 STATUS: LRD_RX_1->signal_level() = -37.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:05: ACU Position: 288.1, 19.32 STATUS: LRD_RX_1->signal_level() = -37.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:05: ACU Position: 288.23, 19.28 STATUS: LRD_RX_1->signal_level() = -37.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:06: ACU Position: 288.36, 19.25 STATUS: LRD_RX_1->signal_level() = -37.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:07: ACU Position: 288.55, 19.23 STATUS: LRD_RX_1->signal_level() = -37.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:07: ACU Position: 288.66, 19.21 STATUS: LRD_RX_1->signal_level() = -38.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:08: ACU Position: 288.79, 19.17 STATUS: LRD_RX_1->signal_level() = -37.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:09: ACU Position: 288.97, 19.12 STATUS: LRD_RX_1->signal_level() = -37.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:09: ACU Position: 289.1, 19.1 STATUS: LRD_RX_1->signal_level() = -37.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:10: ACU Position: 289.23, 19.07 STATUS: LRD_RX_1->signal_level() = -37.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:11: ACU Position: 289.42, 19.03 STATUS: LRD_RX_1->signal_level() = -37.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:11: ACU Position: 289.55, 19 STATUS: LRD_RX_1->signal_level() = -37.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:12: ACU Position: 289.73, 18.97 STATUS: LRD_RX_1->signal_level() = -37.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:13: ACU Position: 289.86, 18.94 STATUS: LRD_RX_1->signal_level() = -38.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:13: ACU Position: 290.03, 18.9 STATUS: LRD_RX_1->signal_level() = -37.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:14: ACU Position: 290.16, 18.88 STATUS: LRD_RX_1->signal_level() = -37.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:15: ACU Position: 290.3, 18.84 STATUS: LRD_RX_1->signal_level() = -38.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:15: ACU Position: 290.44, 18.8 STATUS: LRD_RX_1->signal_level() = -38.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:16: ACU Position: 290.62, 18.77 STATUS: LRD_RX_1->signal_level() = -37.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:17: ACU Position: 290.75, 18.74 STATUS: LRD_RX_1->signal_level() = -37.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:17: ACU Position: 290.88, 18.69 STATUS: LRD_RX_1->signal_level() = -37.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:18: ACU Position: 291.05, 18.67 STATUS: LRD_RX_1->signal_level() = -37.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:19: ACU Position: 291.19, 18.65 STATUS: LRD_RX_1->signal_level() = -37.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:19: ACU Position: 291.32, 18.61 STATUS: LRD_RX_1->signal_level() = -37.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:20: ACU Position: 291.45, 18.58 STATUS: LRD_RX_1->signal_level() = -38.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:21: ACU Position: 291.57, 18.55 STATUS: LRD_RX_1->signal_level() = -37.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:21: ACU Position: 291.68, 18.51 STATUS: LRD_RX_1->signal_level() = -37.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:22: ACU Position: 291.86, 18.47 STATUS: LRD_RX_1->signal_level() = -37.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:23: ACU Position: 291.98, 18.44 STATUS: LRD_RX_1->signal_level() = -37.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:23: ACU Position: 292.1, 18.41 STATUS: LRD_RX_1->signal_level() = -37.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:24: ACU Position: 292.23, 18.36 STATUS: LRD_RX_1->signal_level() = -37.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:24: ACU Position: 292.36, 18.34 STATUS: LRD_RX_1->signal_level() = -37.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:25: ACU Position: 292.53, 18.32 STATUS: LRD_RX_1->signal_level() = -37.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:26: ACU Position: 292.66, 18.28 STATUS: LRD_RX_1->signal_level() = -37.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:26: ACU Position: 292.78, 18.23 STATUS: LRD_RX_1->signal_level() = -37.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:27: ACU Position: 292.96, 18.21 STATUS: LRD_RX_1->signal_level() = -37.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:28: ACU Position: 293.09, 18.18 STATUS: LRD_RX_1->signal_level() = -38.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:28: ACU Position: 293.21, 18.13 STATUS: LRD_RX_1->signal_level() = -37.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:29: ACU Position: 293.33, 18.1 STATUS: LRD_RX_1->signal_level() = -38.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:30: ACU Position: 293.46, 18.06 STATUS: LRD_RX_1->signal_level() = -37.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:30: ACU Position: 293.64, 18.03 STATUS: LRD_RX_1->signal_level() = -38.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:31: ACU Position: 293.76, 17.99 STATUS: LRD_RX_1->signal_level() = -38.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:32: ACU Position: 293.89, 17.96 STATUS: LRD_RX_1->signal_level() = -38.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:32: ACU Position: 294.01, 17.93 STATUS: LRD_RX_1->signal_level() = -38.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:33: ACU Position: 294.17, 17.89 STATUS: LRD_RX_1->signal_level() = -38.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:33: ACU Position: 294.31, 17.87 STATUS: LRD_RX_1->signal_level() = -38.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:34: ACU Position: 294.39, 17.83 STATUS: LRD_RX_1->signal_level() = -38.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:35: ACU Position: 294.53, 17.79 STATUS: LRD_RX_1->signal_level() = -37.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:35: ACU Position: 294.65, 17.75 STATUS: LRD_RX_1->signal_level() = -38.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:36: ACU Position: 294.8, 17.72 STATUS: LRD_RX_1->signal_level() = -38.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:37: ACU Position: 294.92, 17.68 STATUS: LRD_RX_1->signal_level() = -38.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:37: ACU Position: 295.09, 17.64 STATUS: LRD_RX_1->signal_level() = -37.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:38: ACU Position: 295.21, 17.6 STATUS: LRD_RX_1->signal_level() = -38.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:39: ACU Position: 295.37, 17.55 STATUS: LRD_RX_1->signal_level() = -38.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:39: ACU Position: 295.49, 17.53 STATUS: LRD_RX_1->signal_level() = -38.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:40: ACU Position: 295.61, 17.5 STATUS: LRD_RX_1->signal_level() = -38.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:41: ACU Position: 295.73, 17.45 STATUS: LRD_RX_1->signal_level() = -37.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:41: ACU Position: 295.86, 17.42 STATUS: LRD_RX_1->signal_level() = -38.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:42: ACU Position: 296.02, 17.39 STATUS: LRD_RX_1->signal_level() = -38.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:43: ACU Position: 296.14, 17.34 STATUS: LRD_RX_1->signal_level() = -37.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:43: ACU Position: 296.26, 17.31 STATUS: LRD_RX_1->signal_level() = -38.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:44: ACU Position: 296.43, 17.28 STATUS: LRD_RX_1->signal_level() = -38.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:45: ACU Position: 296.55, 17.23 STATUS: LRD_RX_1->signal_level() = -38.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:45: ACU Position: 296.66, 17.2 STATUS: LRD_RX_1->signal_level() = -38.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:46: ACU Position: 296.79, 17.17 STATUS: LRD_RX_1->signal_level() = -38.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:47: ACU Position: 296.91, 17.11 STATUS: LRD_RX_1->signal_level() = -38.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:47: ACU Position: 297.04, 17.09 STATUS: LRD_RX_1->signal_level() = -38.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:48: ACU Position: 297.15, 17.05 STATUS: LRD_RX_1->signal_level() = -38.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:49: ACU Position: 297.27, 17.01 STATUS: LRD_RX_1->signal_level() = -38.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:49: ACU Position: 297.38, 16.98 STATUS: LRD_RX_1->signal_level() = -38.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:50: ACU Position: 297.5, 16.93 STATUS: LRD_RX_1->signal_level() = -38.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:51: ACU Position: 297.66, 16.88 STATUS: LRD_RX_1->signal_level() = -38.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:51: ACU Position: 297.77, 16.86 STATUS: LRD_RX_1->signal_level() = -38.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:52: ACU Position: 297.92, 16.82 STATUS: LRD_RX_1->signal_level() = -38.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:53: ACU Position: 298.04, 16.78 STATUS: LRD_RX_1->signal_level() = -38.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:53: ACU Position: 298.15, 16.76 STATUS: LRD_RX_1->signal_level() = -38.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:54: ACU Position: 298.27, 16.72 STATUS: LRD_RX_1->signal_level() = -38.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:54: ACU Position: 298.38, 16.66 STATUS: LRD_RX_1->signal_level() = -38.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:55: ACU Position: 298.55, 16.63 STATUS: LRD_RX_1->signal_level() = -38.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:56: ACU Position: 298.66, 16.6 STATUS: LRD_RX_1->signal_level() = -38.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:56: ACU Position: 298.77, 16.56 STATUS: LRD_RX_1->signal_level() = -38.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:57: ACU Position: 298.89, 16.52 STATUS: LRD_RX_1->signal_level() = -39.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:58: ACU Position: 299.04, 16.47 STATUS: LRD_RX_1->signal_level() = -39.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:58: ACU Position: 299.15, 16.43 STATUS: LRD_RX_1->signal_level() = -39.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:35:59: ACU Position: 299.27, 16.42 STATUS: LRD_RX_1->signal_level() = -38.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:00: ACU Position: 299.43, 16.36 STATUS: LRD_RX_1->signal_level() = -38.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:00: ACU Position: 299.54, 16.32 STATUS: LRD_RX_1->signal_level() = -39.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:01: ACU Position: 299.62, 16.3 STATUS: LRD_RX_1->signal_level() = -39.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:02: ACU Position: 299.74, 16.23 STATUS: LRD_RX_1->signal_level() = -39.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:02: ACU Position: 299.89, 16.21 STATUS: LRD_RX_1->signal_level() = -39.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:03: ACU Position: 299.99, 16.17 STATUS: LRD_RX_1->signal_level() = -39.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:04: ACU Position: 300.11, 16.12 STATUS: LRD_RX_1->signal_level() = -39.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:04: ACU Position: 300.21, 16.1 STATUS: LRD_RX_1->signal_level() = -39.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:05: ACU Position: 300.35, 16.05 STATUS: LRD_RX_1->signal_level() = -39.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:06: ACU Position: 300.47, 16.01 STATUS: LRD_RX_1->signal_level() = -39.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:06: ACU Position: 300.57, 15.98 STATUS: LRD_RX_1->signal_level() = -39.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:07: ACU Position: 300.68, 15.93 STATUS: LRD_RX_1->signal_level() = -39.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:07: ACU Position: 300.79, 15.89 STATUS: LRD_RX_1->signal_level() = -39.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:08: ACU Position: 300.94, 15.86 STATUS: LRD_RX_1->signal_level() = -39.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:09: ACU Position: 301.04, 15.82 STATUS: LRD_RX_1->signal_level() = -39.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:09: ACU Position: 301.16, 15.77 STATUS: LRD_RX_1->signal_level() = -39.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:10: ACU Position: 301.26, 15.73 STATUS: LRD_RX_1->signal_level() = -39.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:11: ACU Position: 301.4, 15.69 STATUS: LRD_RX_1->signal_level() = -39.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:11: ACU Position: 301.52, 15.65 STATUS: LRD_RX_1->signal_level() = -39.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:12: ACU Position: 301.62, 15.62 STATUS: LRD_RX_1->signal_level() = -39.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:13: ACU Position: 301.73, 15.57 STATUS: LRD_RX_1->signal_level() = -39.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:13: ACU Position: 301.87, 15.54 STATUS: LRD_RX_1->signal_level() = -39.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:14: ACU Position: 301.97, 15.49 STATUS: LRD_RX_1->signal_level() = -39.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:15: ACU Position: 302.08, 15.44 STATUS: LRD_RX_1->signal_level() = -38.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:15: ACU Position: 302.22, 15.42 STATUS: LRD_RX_1->signal_level() = -39.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:16: ACU Position: 302.32, 15.37 STATUS: LRD_RX_1->signal_level() = -39.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:17: ACU Position: 302.43, 15.32 STATUS: LRD_RX_1->signal_level() = -39.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:17: ACU Position: 302.56, 15.3 STATUS: LRD_RX_1->signal_level() = -38.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:18: ACU Position: 302.66, 15.26 STATUS: LRD_RX_1->signal_level() = -39.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:19: ACU Position: 302.77, 15.21 STATUS: LRD_RX_1->signal_level() = -39.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:19: ACU Position: 302.91, 15.17 STATUS: LRD_RX_1->signal_level() = -39.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:20: ACU Position: 303.01, 15.12 STATUS: LRD_RX_1->signal_level() = -39.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:21: ACU Position: 303.12, 15.09 STATUS: LRD_RX_1->signal_level() = -39.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:21: ACU Position: 303.25, 15.04 STATUS: LRD_RX_1->signal_level() = -40.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:22: ACU Position: 303.35, 15 STATUS: LRD_RX_1->signal_level() = -40.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:23: ACU Position: 303.46, 14.98 STATUS: LRD_RX_1->signal_level() = -40.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:23: ACU Position: 303.59, 14.93 STATUS: LRD_RX_1->signal_level() = -40.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:24: ACU Position: 303.69, 14.88 STATUS: LRD_RX_1->signal_level() = -40.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:25: ACU Position: 303.8, 14.84 STATUS: LRD_RX_1->signal_level() = -40.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:25: ACU Position: 303.93, 14.79 STATUS: LRD_RX_1->signal_level() = -40.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:26: ACU Position: 304.03, 14.76 STATUS: LRD_RX_1->signal_level() = -40.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:27: ACU Position: 304.13, 14.71 STATUS: LRD_RX_1->signal_level() = -40.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:27: ACU Position: 304.26, 14.67 STATUS: LRD_RX_1->signal_level() = -40.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:28: ACU Position: 304.36, 14.64 STATUS: LRD_RX_1->signal_level() = -40.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:29: ACU Position: 304.47, 14.59 STATUS: LRD_RX_1->signal_level() = -40.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:29: ACU Position: 304.59, 14.54 STATUS: LRD_RX_1->signal_level() = -41.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:30: ACU Position: 304.7, 14.52 STATUS: LRD_RX_1->signal_level() = -41.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:31: ACU Position: 304.79, 14.45 STATUS: LRD_RX_1->signal_level() = -40.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:31: ACU Position: 304.92, 14.42 STATUS: LRD_RX_1->signal_level() = -40.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:32: ACU Position: 305.02, 14.39 STATUS: LRD_RX_1->signal_level() = -40.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:33: ACU Position: 305.12, 14.34 STATUS: LRD_RX_1->signal_level() = -41.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:33: ACU Position: 305.22, 14.31 STATUS: LRD_RX_1->signal_level() = -40.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:34: ACU Position: 305.3, 14.27 STATUS: LRD_RX_1->signal_level() = -40.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:35: ACU Position: 305.44, 14.22 STATUS: LRD_RX_1->signal_level() = -41.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:35: ACU Position: 305.53, 14.19 STATUS: LRD_RX_1->signal_level() = -41.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:36: ACU Position: 305.63, 14.15 STATUS: LRD_RX_1->signal_level() = -40.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:37: ACU Position: 305.77, 14.09 STATUS: LRD_RX_1->signal_level() = -41.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:37: ACU Position: 305.86, 14.06 STATUS: LRD_RX_1->signal_level() = -41.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:38: ACU Position: 305.96, 14 STATUS: LRD_RX_1->signal_level() = -41.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:39: ACU Position: 306.09, 13.97 STATUS: LRD_RX_1->signal_level() = -40.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:39: ACU Position: 306.18, 13.94 STATUS: LRD_RX_1->signal_level() = -40.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:40: ACU Position: 306.28, 13.89 STATUS: LRD_RX_1->signal_level() = -40.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:41: ACU Position: 306.36, 13.85 STATUS: LRD_RX_1->signal_level() = -39.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:41: ACU Position: 306.49, 13.81 STATUS: LRD_RX_1->signal_level() = -39.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:42: ACU Position: 306.59, 13.76 STATUS: LRD_RX_1->signal_level() = -39.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:43: ACU Position: 306.69, 13.72 STATUS: LRD_RX_1->signal_level() = -39.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:43: ACU Position: 306.79, 13.67 STATUS: LRD_RX_1->signal_level() = -38.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:44: ACU Position: 306.92, 13.64 STATUS: LRD_RX_1->signal_level() = -38.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:44: ACU Position: 307.01, 13.6 STATUS: LRD_RX_1->signal_level() = -38.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:45: ACU Position: 307.09, 13.57 STATUS: LRD_RX_1->signal_level() = -38.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:46: ACU Position: 307.18, 13.52 STATUS: LRD_RX_1->signal_level() = -39.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:46: ACU Position: 307.28, 13.48 STATUS: LRD_RX_1->signal_level() = -39.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:47: ACU Position: 307.4, 13.44 STATUS: LRD_RX_1->signal_level() = -38.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:48: ACU Position: 307.49, 13.41 STATUS: LRD_RX_1->signal_level() = -39.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:48: ACU Position: 307.58, 13.35 STATUS: LRD_RX_1->signal_level() = -39.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:49: ACU Position: 307.68, 13.31 STATUS: LRD_RX_1->signal_level() = -39.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:50: ACU Position: 307.8, 13.28 STATUS: LRD_RX_1->signal_level() = -40.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:50: ACU Position: 307.89, 13.23 STATUS: LRD_RX_1->signal_level() = -40.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:51: ACU Position: 307.97, 13.19 STATUS: LRD_RX_1->signal_level() = -40.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:52: ACU Position: 308.09, 13.16 STATUS: LRD_RX_1->signal_level() = -40.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:52: ACU Position: 308.19, 13.09 STATUS: LRD_RX_1->signal_level() = -40.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:53: ACU Position: 308.26, 13.07 STATUS: LRD_RX_1->signal_level() = -40.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:54: ACU Position: 308.39, 13.03 STATUS: LRD_RX_1->signal_level() = -40.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:54: ACU Position: 308.48, 12.98 STATUS: LRD_RX_1->signal_level() = -40.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:55: ACU Position: 308.57, 12.95 STATUS: LRD_RX_1->signal_level() = -39.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:56: ACU Position: 308.65, 12.9 STATUS: LRD_RX_1->signal_level() = -39.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:56: ACU Position: 308.75, 12.86 STATUS: LRD_RX_1->signal_level() = -39.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:57: ACU Position: 308.87, 12.83 STATUS: LRD_RX_1->signal_level() = -40.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:57: ACU Position: 308.96, 12.78 STATUS: LRD_RX_1->signal_level() = -39.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:58: ACU Position: 309.05, 12.75 STATUS: LRD_RX_1->signal_level() = -39.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:59: ACU Position: 309.14, 12.71 STATUS: LRD_RX_1->signal_level() = -40.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:36:59: ACU Position: 309.24, 12.66 STATUS: LRD_RX_1->signal_level() = -40.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:00: ACU Position: 309.31, 12.62 STATUS: LRD_RX_1->signal_level() = -40.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:01: ACU Position: 309.43, 12.57 STATUS: LRD_RX_1->signal_level() = -40.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:01: ACU Position: 309.52, 12.53 STATUS: LRD_RX_1->signal_level() = -40.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:02: ACU Position: 309.61, 12.49 STATUS: LRD_RX_1->signal_level() = -40.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:03: ACU Position: 309.72, 12.45 STATUS: LRD_RX_1->signal_level() = -40.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:03: ACU Position: 309.81, 12.42 STATUS: LRD_RX_1->signal_level() = -40.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:04: ACU Position: 309.89, 12.37 STATUS: LRD_RX_1->signal_level() = -40.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:05: ACU Position: 309.97, 12.32 STATUS: LRD_RX_1->signal_level() = -40.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:05: ACU Position: 310.09, 12.3 STATUS: LRD_RX_1->signal_level() = -40.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:06: ACU Position: 310.16, 12.25 STATUS: LRD_RX_1->signal_level() = -40.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:07: ACU Position: 310.25, 12.19 STATUS: LRD_RX_1->signal_level() = -40.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:07: ACU Position: 310.36, 12.17 STATUS: LRD_RX_1->signal_level() = -41.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:08: ACU Position: 310.45, 12.12 STATUS: LRD_RX_1->signal_level() = -40.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:09: ACU Position: 310.52, 12.08 STATUS: LRD_RX_1->signal_level() = -41.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:09: ACU Position: 310.64, 12.04 STATUS: LRD_RX_1->signal_level() = -41.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:10: ACU Position: 310.72, 11.99 STATUS: LRD_RX_1->signal_level() = -41.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:11: ACU Position: 310.82, 11.95 STATUS: LRD_RX_1->signal_level() = -41.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:11: ACU Position: 310.92, 11.9 STATUS: LRD_RX_1->signal_level() = -40.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:12: ACU Position: 311.01, 11.87 STATUS: LRD_RX_1->signal_level() = -40.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:13: ACU Position: 311.09, 11.82 STATUS: LRD_RX_1->signal_level() = -40.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:13: ACU Position: 311.2, 11.77 STATUS: LRD_RX_1->signal_level() = -40.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:14: ACU Position: 311.29, 11.74 STATUS: LRD_RX_1->signal_level() = -40.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:15: ACU Position: 311.4, 11.7 STATUS: LRD_RX_1->signal_level() = -41.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:15: ACU Position: 311.49, 11.65 STATUS: LRD_RX_1->signal_level() = -41.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:16: ACU Position: 311.58, 11.63 STATUS: LRD_RX_1->signal_level() = -41.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:17: ACU Position: 311.65, 11.56 STATUS: LRD_RX_1->signal_level() = -41.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:17: ACU Position: 311.74, 11.52 STATUS: LRD_RX_1->signal_level() = -41.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:18: ACU Position: 311.85, 11.49 STATUS: LRD_RX_1->signal_level() = -41.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:19: ACU Position: 311.92, 11.45 STATUS: LRD_RX_1->signal_level() = -41.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:19: ACU Position: 311.99, 11.41 STATUS: LRD_RX_1->signal_level() = -41.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:20: ACU Position: 312.1, 11.37 STATUS: LRD_RX_1->signal_level() = -41.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:21: ACU Position: 312.18, 11.32 STATUS: LRD_RX_1->signal_level() = -41.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:21: ACU Position: 312.26, 11.29 STATUS: LRD_RX_1->signal_level() = -41.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:22: ACU Position: 312.34, 11.25 STATUS: LRD_RX_1->signal_level() = -41.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:22: ACU Position: 312.44, 11.2 STATUS: LRD_RX_1->signal_level() = -41.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:23: ACU Position: 312.52, 11.17 STATUS: LRD_RX_1->signal_level() = -41.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:24: ACU Position: 312.6, 11.12 STATUS: LRD_RX_1->signal_level() = -41.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:24: ACU Position: 312.68, 11.09 STATUS: LRD_RX_1->signal_level() = -41.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:25: ACU Position: 312.76, 11.04 STATUS: LRD_RX_1->signal_level() = -41.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:26: ACU Position: 312.86, 11 STATUS: LRD_RX_1->signal_level() = -42.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:26: ACU Position: 312.94, 10.96 STATUS: LRD_RX_1->signal_level() = -41.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:27: ACU Position: 313.05, 10.92 STATUS: LRD_RX_1->signal_level() = -41.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:28: ACU Position: 313.13, 10.87 STATUS: LRD_RX_1->signal_level() = -41.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:28: ACU Position: 313.2, 10.84 STATUS: LRD_RX_1->signal_level() = -42.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:29: ACU Position: 313.29, 10.79 STATUS: LRD_RX_1->signal_level() = -41.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:30: ACU Position: 313.36, 10.75 STATUS: LRD_RX_1->signal_level() = -41.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:30: ACU Position: 313.47, 10.71 STATUS: LRD_RX_1->signal_level() = -41.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:31: ACU Position: 313.54, 10.66 STATUS: LRD_RX_1->signal_level() = -41.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:32: ACU Position: 313.63, 10.63 STATUS: LRD_RX_1->signal_level() = -42.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:32: ACU Position: 313.73, 10.59 STATUS: LRD_RX_1->signal_level() = -42.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:33: ACU Position: 313.8, 10.54 STATUS: LRD_RX_1->signal_level() = -42.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:34: ACU Position: 313.87, 10.51 STATUS: LRD_RX_1->signal_level() = -42.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:34: ACU Position: 313.98, 10.45 STATUS: LRD_RX_1->signal_level() = -42.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:35: ACU Position: 314.06, 10.41 STATUS: LRD_RX_1->signal_level() = -41.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:36: ACU Position: 314.14, 10.39 STATUS: LRD_RX_1->signal_level() = -41.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:36: ACU Position: 314.21, 10.32 STATUS: LRD_RX_1->signal_level() = -41.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:37: ACU Position: 314.29, 10.31 STATUS: LRD_RX_1->signal_level() = -41.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:38: ACU Position: 314.38, 10.26 STATUS: LRD_RX_1->signal_level() = -41.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:38: ACU Position: 314.46, 10.22 STATUS: LRD_RX_1->signal_level() = -41.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:39: ACU Position: 314.53, 10.18 STATUS: LRD_RX_1->signal_level() = -41.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:40: ACU Position: 314.62, 10.14 STATUS: LRD_RX_1->signal_level() = -41.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:40: ACU Position: 314.7, 10.09 STATUS: LRD_RX_1->signal_level() = -41.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:41: ACU Position: 314.76, 10.06 STATUS: LRD_RX_1->signal_level() = -41.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:41: ACU Position: 314.84, 10.03 STATUS: LRD_RX_1->signal_level() = -42.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:42: ACU Position: 314.92, 9.96 STATUS: LRD_RX_1->signal_level() = -42.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:43: ACU Position: 315.02, 9.95 STATUS: LRD_RX_1->signal_level() = -41.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:43: ACU Position: 315.08, 9.89 STATUS: LRD_RX_1->signal_level() = -41.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:44: ACU Position: 315.16, 9.86 STATUS: LRD_RX_1->signal_level() = -42.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:45: ACU Position: 315.25, 9.82 STATUS: LRD_RX_1->signal_level() = -42.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:45: ACU Position: 315.31, 9.77 STATUS: LRD_RX_1->signal_level() = -41.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:46: ACU Position: 315.39, 9.73 STATUS: LRD_RX_1->signal_level() = -41.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:47: ACU Position: 315.49, 9.69 STATUS: LRD_RX_1->signal_level() = -41.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:47: ACU Position: 315.57, 9.64 STATUS: LRD_RX_1->signal_level() = -41.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:48: ACU Position: 315.63, 9.62 STATUS: LRD_RX_1->signal_level() = -41.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:49: ACU Position: 315.73, 9.56 STATUS: LRD_RX_1->signal_level() = -42.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:49: ACU Position: 315.8, 9.52 STATUS: LRD_RX_1->signal_level() = -42.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:50: ACU Position: 315.87, 9.48 STATUS: LRD_RX_1->signal_level() = -42.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:51: ACU Position: 315.97, 9.43 STATUS: LRD_RX_1->signal_level() = -41.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:51: ACU Position: 316.04, 9.41 STATUS: LRD_RX_1->signal_level() = -41.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:52: ACU Position: 316.11, 9.36 STATUS: LRD_RX_1->signal_level() = -42.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:53: ACU Position: 316.18, 9.3 STATUS: LRD_RX_1->signal_level() = -42.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:53: ACU Position: 316.29, 9.28 STATUS: LRD_RX_1->signal_level() = -41.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:54: ACU Position: 316.36, 9.25 STATUS: LRD_RX_1->signal_level() = -41.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:55: ACU Position: 316.43, 9.19 STATUS: LRD_RX_1->signal_level() = -42.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:55: ACU Position: 316.52, 9.16 STATUS: LRD_RX_1->signal_level() = -42.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:56: ACU Position: 316.6, 9.12 STATUS: LRD_RX_1->signal_level() = -42.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:57: ACU Position: 316.66, 9.07 STATUS: LRD_RX_1->signal_level() = -41.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:57: ACU Position: 316.73, 9.04 STATUS: LRD_RX_1->signal_level() = -42.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:58: ACU Position: 316.82, 8.98 STATUS: LRD_RX_1->signal_level() = -42.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:59: ACU Position: 316.87, 8.95 STATUS: LRD_RX_1->signal_level() = -42.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:37:59: ACU Position: 316.97, 8.91 STATUS: LRD_RX_1->signal_level() = -41.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:00: ACU Position: 317.04, 8.85 STATUS: LRD_RX_1->signal_level() = -42.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:01: ACU Position: 317.13, 8.83 STATUS: LRD_RX_1->signal_level() = -42.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:01: ACU Position: 317.19, 8.78 STATUS: LRD_RX_1->signal_level() = -41.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:02: ACU Position: 317.26, 8.74 STATUS: LRD_RX_1->signal_level() = -41.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:03: ACU Position: 317.34, 8.7 STATUS: LRD_RX_1->signal_level() = -42.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:03: ACU Position: 317.41, 8.66 STATUS: LRD_RX_1->signal_level() = -42.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:04: ACU Position: 317.48, 8.62 STATUS: LRD_RX_1->signal_level() = -42.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:05: ACU Position: 317.54, 8.58 STATUS: LRD_RX_1->signal_level() = -42.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:05: ACU Position: 317.63, 8.53 STATUS: LRD_RX_1->signal_level() = -42.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:06: ACU Position: 317.71, 8.51 STATUS: LRD_RX_1->signal_level() = -42.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:07: ACU Position: 317.76, 8.47 STATUS: LRD_RX_1->signal_level() = -41.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:07: ACU Position: 317.84, 8.41 STATUS: LRD_RX_1->signal_level() = -42.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:08: ACU Position: 317.93, 8.39 STATUS: LRD_RX_1->signal_level() = -42.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:09: ACU Position: 317.99, 8.33 STATUS: LRD_RX_1->signal_level() = -42.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:09: ACU Position: 318.06, 8.3 STATUS: LRD_RX_1->signal_level() = -42.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:10: ACU Position: 318.12, 8.27 STATUS: LRD_RX_1->signal_level() = -41.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:11: ACU Position: 318.19, 8.21 STATUS: LRD_RX_1->signal_level() = -42.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:11: ACU Position: 318.28, 8.19 STATUS: LRD_RX_1->signal_level() = -42.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:12: ACU Position: 318.33, 8.16 STATUS: LRD_RX_1->signal_level() = -42.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:13: ACU Position: 318.4, 8.1 STATUS: LRD_RX_1->signal_level() = -42.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:13: ACU Position: 318.49, 8.07 STATUS: LRD_RX_1->signal_level() = -42.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:14: ACU Position: 318.55, 8.02 STATUS: LRD_RX_1->signal_level() = -42.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:15: ACU Position: 318.62, 7.98 STATUS: LRD_RX_1->signal_level() = -42.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:15: ACU Position: 318.71, 7.95 STATUS: LRD_RX_1->signal_level() = -42.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:16: ACU Position: 318.77, 7.91 STATUS: LRD_RX_1->signal_level() = -42.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:17: ACU Position: 318.84, 7.85 STATUS: LRD_RX_1->signal_level() = -42.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:17: ACU Position: 318.94, 7.83 STATUS: LRD_RX_1->signal_level() = -42.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:18: ACU Position: 318.99, 7.78 STATUS: LRD_RX_1->signal_level() = -42.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:19: ACU Position: 319.07, 7.75 STATUS: LRD_RX_1->signal_level() = -42.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:19: ACU Position: 319.14, 7.71 STATUS: LRD_RX_1->signal_level() = -42.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:20: ACU Position: 319.19, 7.66 STATUS: LRD_RX_1->signal_level() = -42.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:20: ACU Position: 319.28, 7.62 STATUS: LRD_RX_1->signal_level() = -42.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:21: ACU Position: 319.33, 7.6 STATUS: LRD_RX_1->signal_level() = -42.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:22: ACU Position: 319.4, 7.54 STATUS: LRD_RX_1->signal_level() = -43.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:22: ACU Position: 319.47, 7.51 STATUS: LRD_RX_1->signal_level() = -42.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:23: ACU Position: 319.54, 7.48 STATUS: LRD_RX_1->signal_level() = -42.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:24: ACU Position: 319.61, 7.43 STATUS: LRD_RX_1->signal_level() = -42.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:24: ACU Position: 319.65, 7.4 STATUS: LRD_RX_1->signal_level() = -42.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:25: ACU Position: 319.73, 7.36 STATUS: LRD_RX_1->signal_level() = -42.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:26: ACU Position: 319.79, 7.31 STATUS: LRD_RX_1->signal_level() = -41.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:26: ACU Position: 319.85, 7.29 STATUS: LRD_RX_1->signal_level() = -42.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:27: ACU Position: 319.94, 7.24 STATUS: LRD_RX_1->signal_level() = -42.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:28: ACU Position: 319.99, 7.19 STATUS: LRD_RX_1->signal_level() = -42.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:28: ACU Position: 320.05, 7.16 STATUS: LRD_RX_1->signal_level() = -42.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:29: ACU Position: 320.14, 7.11 STATUS: LRD_RX_1->signal_level() = -42.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:30: ACU Position: 320.19, 7.08 STATUS: LRD_RX_1->signal_level() = -42.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:30: ACU Position: 320.26, 7.03 STATUS: LRD_RX_1->signal_level() = -42.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:31: ACU Position: 320.32, 7 STATUS: LRD_RX_1->signal_level() = -42.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:32: ACU Position: 320.38, 6.96 STATUS: LRD_RX_1->signal_level() = -42.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:32: ACU Position: 320.46, 6.91 STATUS: LRD_RX_1->signal_level() = -42.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:33: ACU Position: 320.54, 6.87 STATUS: LRD_RX_1->signal_level() = -42.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:34: ACU Position: 320.6, 6.85 STATUS: LRD_RX_1->signal_level() = -42.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:34: ACU Position: 320.66, 6.81 STATUS: LRD_RX_1->signal_level() = -42.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:35: ACU Position: 320.74, 6.76 STATUS: LRD_RX_1->signal_level() = -42.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:36: ACU Position: 320.81, 6.72 STATUS: LRD_RX_1->signal_level() = -41.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:36: ACU Position: 320.86, 6.68 STATUS: LRD_RX_1->signal_level() = -42.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:37: ACU Position: 320.94, 6.63 STATUS: LRD_RX_1->signal_level() = -42.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:38: ACU Position: 320.99, 6.61 STATUS: LRD_RX_1->signal_level() = -43.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:38: ACU Position: 321.06, 6.54 STATUS: LRD_RX_1->signal_level() = -42.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:39: ACU Position: 321.11, 6.52 STATUS: LRD_RX_1->signal_level() = -42.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:40: ACU Position: 321.2, 6.49 STATUS: LRD_RX_1->signal_level() = -42.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:40: ACU Position: 321.26, 6.44 STATUS: LRD_RX_1->signal_level() = -42.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:41: ACU Position: 321.32, 6.41 STATUS: LRD_RX_1->signal_level() = -42.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:42: ACU Position: 321.4, 6.37 STATUS: LRD_RX_1->signal_level() = -42.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:42: ACU Position: 321.48, 6.31 STATUS: LRD_RX_1->signal_level() = -42.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:43: ACU Position: 321.54, 6.29 STATUS: LRD_RX_1->signal_level() = -42.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:44: ACU Position: 321.6, 6.25 STATUS: LRD_RX_1->signal_level() = -42.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:44: ACU Position: 321.66, 6.21 STATUS: LRD_RX_1->signal_level() = -42.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:45: ACU Position: 321.72, 6.17 STATUS: LRD_RX_1->signal_level() = -42.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:46: ACU Position: 321.78, 6.13 STATUS: LRD_RX_1->signal_level() = -42.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:46: ACU Position: 321.84, 6.09 STATUS: LRD_RX_1->signal_level() = -42.9 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:47: ACU Position: 321.9, 6.07 STATUS: LRD_RX_1->signal_level() = -42.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:48: ACU Position: 321.95, 6.02 STATUS: LRD_RX_1->signal_level() = -42.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:48: ACU Position: 322.02, 5.98 STATUS: LRD_RX_1->signal_level() = -42.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:49: ACU Position: 322.08, 5.95 STATUS: LRD_RX_1->signal_level() = -42.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:50: ACU Position: 322.13, 5.91 STATUS: LRD_RX_1->signal_level() = -42.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:50: ACU Position: 322.19, 5.86 STATUS: LRD_RX_1->signal_level() = -42.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:51: ACU Position: 322.23, 5.83 STATUS: LRD_RX_1->signal_level() = -42.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:51: ACU Position: 322.29, 5.79 STATUS: LRD_RX_1->signal_level() = -42.3 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:52: ACU Position: 322.35, 5.75 STATUS: LRD_RX_1->signal_level() = -42.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:53: ACU Position: 322.42, 5.73 STATUS: LRD_RX_1->signal_level() = -43.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:53: ACU Position: 322.46, 5.69 STATUS: LRD_RX_1->signal_level() = -43.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:54: ACU Position: 322.52, 5.64 STATUS: LRD_RX_1->signal_level() = -43.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:55: ACU Position: 322.59, 5.61 STATUS: LRD_RX_1->signal_level() = -43.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:55: ACU Position: 322.65, 5.58 STATUS: LRD_RX_1->signal_level() = -43.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:56: ACU Position: 322.71, 5.52 STATUS: LRD_RX_1->signal_level() = -42.8 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:57: ACU Position: 322.78, 5.49 STATUS: LRD_RX_1->signal_level() = -43.1 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:57: ACU Position: 322.84, 5.46 STATUS: LRD_RX_1->signal_level() = -42.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:58: ACU Position: 322.88, 5.42 STATUS: LRD_RX_1->signal_level() = -41.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:59: ACU Position: 322.95, 5.4 STATUS: LRD_RX_1->signal_level() = -42.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:38:59: ACU Position: 323, 5.36 STATUS: LRD_RX_1->signal_level() = -42.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:39:00: ACU Position: 323.05, 5.3 STATUS: LRD_RX_1->signal_level() = -42.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:39:01: ACU Position: 323.12, 5.28 STATUS: LRD_RX_1->signal_level() = -42.7 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:39:01: ACU Position: 323.18, 5.24 STATUS: LRD_RX_1->signal_level() = -42.6 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:39:02: ACU Position: 323.23, 5.19 STATUS: LRD_RX_1->signal_level() = -43.0 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:39:03: ACU Position: 323.31, 5.16 STATUS: LRD_RX_1->signal_level() = -43.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:39:03: ACU Position: 323.37, 5.13 STATUS: LRD_RX_1->signal_level() = -43.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:39:04: ACU Position: 323.41, 5.07 STATUS: LRD_RX_1->signal_level() = -42.4 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:39:04: ACU Position: 323.46, 5.05 STATUS: LRD_RX_1->signal_level() = -42.5 STATUS: LRD_RX_1->lock_status() = FR STATUS: 16-Jun-2025 03:39:05: ACU Position: 323.53, 5.02 STATUS: LRD_RX_1->signal_level() = -42.2 STATUS: LRD_RX_1->lock_status() = FR STATUS: OrbitalSystems::tracker_child::terminate_tracking(): Database idPass for this pass: 253351 STATUS: OrbitalSystems::tracker_child::terminate_tracking(): Finished tracking 'NOAA 19' for this pass. Pedestal: Pedestal_1(24_AEBP). End Az, El: 323.595672895916, 4.9635863553083. STATUS: OrbitalSystems::Hardware::Pedestal::DownlinkController::End_Downlink(): Setting up LOS downlink parameters for Pedestal_1(24_AEBP) and NOAA 19 STATUS: OrbitalSystems::Hardware::Pedestal::DownlinkController::End_Downlink(): Successfully set LOS downlink parameter LRD_Ingestor_1->terminate( 1 ). STATUS: OrbitalSystems::tracker_child::ingest_cleanup(): Attempting to find files from this pass... STATUS: OrbitalSystems::IngestData::Add_Swath_Products(): @files: /opt/orbital_systems/data/NOAA/level0/NOAA19.20250616.032803.hrpt /opt/orbital_systems/data/NOAA/images/NOAA19.20250616.032803.png /opt/orbital_systems/data/NOAA/raw/NOAA19.20250616.032756.dat STATUS: OrbitalSystems::EOSDATA::Add_SwathProduct(): Adding file /opt/orbital_systems/data/NOAA/level0/NOAA19.20250616.032803.hrpt to the database as a StoredFile... STATUS: OrbitalSystems::EOSDATA::Add_SwathProduct(): New idStoredFile = 1457963 STATUS: OrbitalSystems::EOSDATA::Add_SwathProduct(): New idSwathProduct = 1365396 STATUS: OrbitalSystems::EOSDATA::Process_FTPPushSubscription(): Processing FTPPushSubscriptions for SwathProduct id = 1365396. STATUS: OrbitalSystems::EOSDATA::Process_FTPPushSubscription(): Found subscription id = 16. STATUS: OrbitalSystems::EOSDATA::FTP_Push_File(): Adding file NOAA19.20250616.032803.hrpt to FTP Push Server queue for server DBPS... STATUS: OrbitalSystems::EOSDATA::Process_FTPPushSubscription(): Found subscription id = 50. STATUS: OrbitalSystems::EOSDATA::FTP_Push_File(): Adding file NOAA19.20250616.032803.hrpt to FTP Push Server queue for server SSEC_FTP... STATUS: OrbitalSystems::EOSDATA::Add_SwathProduct(): Adding file /opt/orbital_systems/data/NOAA/images/NOAA19.20250616.032803.png to the database as a StoredFile... STATUS: OrbitalSystems::EOSDATA::Add_SwathProduct(): New idStoredFile = 1457964 STATUS: OrbitalSystems::EOSDATA::Add_SwathProduct(): New idSwathProduct = 1365397 STATUS: OrbitalSystems::EOSDATA::Process_FTPPushSubscription(): Processing FTPPushSubscriptions for SwathProduct id = 1365397. STATUS: OrbitalSystems::EOSDATA::Add_SwathProduct(): Adding file /opt/orbital_systems/data/NOAA/raw/NOAA19.20250616.032756.dat to the database as a StoredFile... STATUS: OrbitalSystems::EOSDATA::Add_SwathProduct(): New idStoredFile = 1457965 STATUS: OrbitalSystems::EOSDATA::Add_SwathProduct(): New idSwathProduct = 1365398 STATUS: OrbitalSystems::EOSDATA::Process_FTPPushSubscription(): Processing FTPPushSubscriptions for SwathProduct id = 1365398. STATUS: OrbitalSystems::tracker_child::start_check_files(): Creating CHECK_FILES work order: /opt/orbital_systems/post_process/check_files/DO.CHECK_FILES.20250616.033936.NOAA_19.Pass253351.wo. STATUS: OrbitalSystems::tracker_child::terminate_tracking(): Cleaning up ScheduleItem id=213525 STATUS: OrbitalSystems::Schedule::Delete_Scheduled_Item(): Deleting ScheduleItem with id = 213525 STATUS: OrbitalSystems::tracker_child::terminate_tracking(): Sending Email Notifications STATUS: OrbitalSystems::tracker_child::terminate_tracking(): Launching Post Processing STATUS: OrbitalSystems::tracker_child::start_post_processing(): Creating post-process work order: /opt/orbital_systems/post_process/is_quicklook/DO.IS_QUICKLOOK.20250616.033936.NOAA_19.Pass253351.wo. STATUS: OrbitalSystems::tracker_child::start_post_processing(): Creating post-process work order: /opt/orbital_systems/post_process/noaa_aapp_l1b/DO.NOAA_AAPP_LEVEL1B.20250616.033936.NOAA_19.Pass253351.wo. STATUS: OrbitalSystems::TrackLogger::DataLogger::preprocess_data(): Propagating lock_status to signal_level for LRD_RX_1. STATUS: OrbitalSystems::TrackLogger::DataLogger::write_data_file(): Writing CSV data: /opt/orbital_systems/log/track_logs/Track.20250616.032754.Pedestal_1.NOAA_19/LRD_RX_1.csv STATUS: OrbitalSystems::TrackLogger::DataLogger::write_data_file(): Writing CSV data: /opt/orbital_systems/log/track_logs/Track.20250616.032754.Pedestal_1.NOAA_19/Pedestal_1.csv STATUS: OrbitalSystems::TrackLogger::DataLogger::write_plots(): Running command: /usr/bin/gnuplot /opt/orbital_systems/log/track_logs/Track.20250616.032754.Pedestal_1.NOAA_19/gnuplot.gnu >/opt/orbital_systems/log/track_logs/Track.20250616.032754.Pedestal_1.NOAA_19/track_plots.png STATUS: OrbitalSystems::TrackLogger::DataLogger::write_plots(): gnuplot exited with value 0 - /opt/orbital_systems/bin/tracker_child.pl 1.159 17829 ending with SUCCESS at Mon Jun 16 03:39:36 2025 ------------------------------------------------------------------------------- - /opt/orbital_systems/bin/tracker_child.pl 1.159 17829 ending with SUCCESS at Mon Jun 16 03:39:36 2025 -------------------------------------------------------------------------------